COMPLETE ELECTRONIC FLUSHING SYSTEMS
Wall-Recessed
Professional

Technical specifications:
• Operation A (detection): VELO Activation.
• Start working inzial mosturizing flushing: 2 sec after detection.
• Operation B Main flushing activation: 8sec after continuous
detection.
• Main flushing operated (only if preactivate): 3 seconds after
the user moves away.
• Flushing period: 4 seconds not adjustable.
• Operation C: Floor washer start working after 5 min of last
detection.
• Interruption: Automatic shutoff 10min after continuous
functioning.
• Operating pressure: 1-10bar.
• Quantity of flushable water: Adjusted at 7L+5L for floor
washer.
• Supply: 230/12Vac 6VA safety transformer Class II IP65.
Version available:
• VAIDIM/9T/D: DISABLED
• VAIDIM/9T/B: CHILDREN

VAIDIM9

WALL-RECESSED FLUSHING CISTERN WITH FLOOR-WASHING SYSTEM

• Heavy duty.
• WC Unit: Complete.
• Toilet bowl: Suspended.
• Colour: White ceramic.
• Toilet seat: Not included (Butterfly: Pag.38 catalogue).
• Included: Connection pipes & screw studs for fixing the toilet bowl and galvanized steel structures for self-sustaining the system.
• Flushing System: Electronic/Wall built-in.
• Flushometer: V417.
• Activity: Flushing throught a water tank.
• Equipped for floor tank washing under grating (PAVIM/WC e PAVIM/OR).
• Electronic wall built-in control: Single cover plate.
• Fitted: filter and stopcock.
• Security: Manual push button for flushing in Solid brass.
• Hydraulic part: In solid brass.
• VELO Anti-stick: water film flow for pre-moistening basin interiors.
• Infrared electronic circuits with incorporated automatic shutoff system: after 3 min of continuous functioning.
• Components housed inside.
• External cover plate: Single plate in 2 mm thick AISI 316 Stainless steel secured with 2 vandal proof stainless steel screws.
• Equipped: with 230/12Vac safety transformer and soundproof waste piping.
• CE Certified.

Technical specifications:
• Operation A (detection): VELO Activation.
• Start working inzial mosturizing flushing: 2 sec after detection.
• Operation B Main flushing activation: 8sec after continuous
detection.
• Main flushing operated (only if preactivate): 3 seconds after
the user moves away.
• Flushing period: 4 seconds not adjustable.
• Operation C: Floor washer start working after 5 min of last
detection.
• Interruption: Automatic shutoff 10min after continuous
functioning.
• Operating pressure: 1-10bar.
• Quantity of flushable water: Adjusted at 7L+5L for floor
washer.
• Supply: 230/12Vac 6VA safety transformer Class II IP65.
Version available:
• VAIDIM/9T/D: DISABLED
• VAIDIM/9T/B: CHILDREN

for people without disabilities VADIM/9T12Vac
for people with disabilities VADIM/9T/D12Vac
for kids VADIM/9T/B12Vac
VAIDIM/7T/* intake system VADIM/9T/*/ASP12Vac